Contador Automático de Células modelo LUNA-II™


  • NEW AUTOFOCUSING TECHNOLOGY


    The LUNA-II™ automated cell counter has integrated a novel focusing mechanism based on liquid lens technology.


    The liquid lens does not use any mechanical moving parts to change the Z
    stage. Instead, the Z position of the sample is rapidly

    obtained by the application of a small voltage to the liquid lens. The
    elimination of moving parts removes noise and significantly

    reduces the need for servicing. Even after multi-million cycles of
    focusing, the liquid lens does not require repair or service.

    In combination with this novel focusing mechanism, the LUNA-II™ has integrated a new autofocusing algorithm optimized for

    cell counting.


    CELL COUNTING ACCURACY : DE-CLUSTERIN

  • The LUNA-II™ automated cell counting algorithm has been recognized to have the best-in-class cell counting accuracy. 

  • The LUNA™ software has exceptional accuracy in cell de-clustering and
    can successfully count clumpy cells. The LUNA-II™ automated cell counter has inherited this well-known performance aspect of the LUNA™ software. Clumpy cells are de-clustered quickly and automatically, then counted as individual cells.   

    ERYTHROSIN B AND TRYPAN BLUE-COMPATIBLE

    Although the LUNA-II™ can detect and count unstained
    cells, viability information can only be obtained from stained cell
    solutions.
    The traditional trypan blue can be used with the LUNA-II™, as well as
    the safer Erythrosin B. Both dyes produce consistently accurate
    cell count and viability data with the LUNA-II™.



    Read the following article for more information on Erythrosin B-stained cell viability data.


  • REDUCED RUNNING COST


    Automated cell counters utilize disposable counting slides to eliminate washing steps of manual cell counting with the glass hemocytometer. Although disposable cell counting slides have several
    advantages, the increased running cost has been a substantial concern. Logos Biosystems developed a patented T-BOND technology to
    manufacture precision cell counting slides more efficiently.

    Therefore, the unit price of counting slides became much more affordable, providing significant cost savings.  

    BUILT – IN PRINTER


    A thermal printer is integrated in the LUNA-II™ automated cell counter, and the counting results can be printed immediately for

    record keeping purposes. Because the printer is already integrated in the LUNA-II™ automated cell counter, an additional cable

    connection is not required.


  • INTERACTIVE SOFTWARE INTERFACE

    Options for staining methods


    The LUNA-II™ automated cell counter can count samples with or without trypan blue dye. The selection of trypan blue presence

    or absence can easily be chosen in the settings menu.


    Cell size histogram and cell size based gating


    After counting, cells can be gated based on their size information
    provided by the LUNA-II™. The specific size of cell populations

    Can easily be included or excluded on histograms.


    Cell cluster map


    Counted cells can be sorted with cell cluster map, into single cells, doublets, or triplets.

    The cell cluster map can be used to monitor changes in culture conditions or cell isolation/preparation protocols.


    Review and Re-analysis option


    The LUNA-II™ automated cell counter provides a powerful review option.

    A separate PC unnecessary. Users can open cell images directly on the LUNA-II™ automated cell counter

    to check previous results.


    Various file save options


    The LUNA-II™ can store up to 1,000 counts onboard. After counting, the
    result is automatically saved in the memory, and previous count results
    can be exported via USB as a .CSV file for further analysis. The
    results and image data can be saved in three different file formats such
    as TIF, annotated TIF, or a PDF report file. The PDF report file
    contains all the data generated during/after the cell counting, i.e.,
    the protocol used, cell counting results, date, raw/analyzed cell
    image(s), and histograms are included in the PDF report file.  

  • Acessórios
    L40001
    LUNA-II™ Automated Cell Counter (with built-in printer)


    1 unit


    L40002
    LUNA-II™ Automated Cell Counter (without printer)


    1 unit


    L12008
    LUNA™ Reusable Slide


    1 unit


    L12010
    LUNA™ Reusable Slide Coverslips


    10 units


    L12001
    LUNA™ Cell Counting Slides, 50 Slides


    1 box


    L12002
    LUNA™ Cell Counting Slides, 500 Slides


    10 boxes


    L12003
    LUNA™ Cell Counting Slides, 1000 Slides


    20 boxes


    T13101
    Trypan Blue Stain, 0.4%


    2 X 1 mL


    L13002
    Erythrosin B Stain


    2 x 1 mL


    B13101
    LUNA™ Standard Beads


    2 X 1 mL


    P12002
    LUNA-II™ Printer Paper - thermal, 700 prints


    2 x 5 rolls


    U10005
    USB Drive, 16 GB
    1 unit 

    Para informações técnicas, clique aqui

    Para contato de um representante de vendas clique aqui

    ASSISTÊNCIA TÉCNICA
    ASSESSORIA DE PRODUTOS
    DEMONSTRAÇÃO DE PRODUTOS
    SUPORTE A CLIENTES
    REDES SOCIAIS

    Facebook Linkedin

    CONTATO